GENERAL PURPOSE SPECIALTY
IS800 Series(1)
IS806 FRV1106 RTV1473
Data Sheets Technical Data Sheets Technical Data Sheet
Features Paste adhesive with FDA, USDA, and NSFcompliance. UL94 HB recognition High temperature, paste adhesive with FDA, USDA, and NSF compliance. recognition.UL94 HB Fluorosilicone, paste adhesive. Excellent resistance to fuel, oil, moisture, UV, ozone and chemicals. Oil-resistant, heavy-bodied, paste adhesive.
Typical Applications (include but not limited to) Sealing and bonding. Sealing and bonding. Formed-in-place gasketing; Sealing seams; Fuel handling systems; Sealing
and bonding; Valve manufacturers.
Formed-in-place gasketing; Sealing and bonding.
Key Substrate Adhesion Primerless adhesion to many metals, plastics and glass. Primerless adhesion to many metals, plastics and glass. Primerless adhesion to many metals, plastics and glass. Primerless adhesion to many metals, plastics and glass.
Color
(Final Product)
IS802: White
IS803: Black Translucent
IS808: IS800.09: Aluminum
Red Red Black
Viscosity (cps)/ Application Rate (g/min) 425 g/min 550 g/min 92 g/min 375 g/min
Useful Temperature Range -60 to 205°C
(-75 to 400°F)
-60 to 260°C
(-75 to 500°F)
-60 to 205°C
(-75 to 400°F)
-60 to 205°C
(-75 to 400°F)
Speci?c Gravity 1.04 1.05 1.45 1.06
Hardness, Shore A Durometer 23 22 39 30
Tensile Strength
(psi)
300 250 485 450
Elongation (%) 450 425 200 500
Dielectric Strength
(75 mils, V/mil)
500 500
Dielectric Constant
(60 Hz)
2.90 2.90
Linear Shrinkage (%)
Processing:
Tack Free Time
30 minutes 30 minutes 20 minutes 25 minutes
Cure Time @ 25°C (77°F)++ 24 hours 24 hours 24 hours 24 hours
  • Note: Additional information may be available on the technical datasheet. This chart contains typical property values and actual values or results may vary.
  • + These sealants are not for use in delicate electrical and electronic applications in which corrosion of copper, brass and other sensitive metals is undesirable.
  • Cure times are typical values which may be affected by bead size, temperature, relative humidity, and the equipment used.
    Full property development with standard condensation cure products may take 3 to 7+ days (at 25°C and 50% RH).
  • (1) IS802 does not currently meet FDA regulation 21CFR177.2600 “Rubber Articles Intended for Repeated Use.”